WARNING: If the information in this manual is not fol-
lowed exactly, a fi re or explosion may result causing
property damage, personal injury, or loss of life.
Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call the
re department.
Installation and service must be performed by
a qualifi ed installer, service agency, or the gas
supplier.
WARNING: Improper installation,
adjustment, alteration, service,
or maintenance can cause injury
or property damage. Refer to this
manual for correct installation and
operational procedures. For as-
sistance or additional information
consult a qualifi ed installer, service
agency, or the gas supplier.
WARNING: This appliance is for
installation only in a solid-fuel burn-
ing masonry or UL127 factory-built
replace, constructed of noncom-
bustible material, and connected
to a working fl ue. (See page 7 for
minimum fl ue opening.)
RGA 2-72
APPROVED
TESTED AND
LISTED BY
VENTED DECORATIVE NATURAL GAS LOGS
OWNER’S OPERATION AND
INSTALLATION MANUAL
WARNING: This is a gas-fi red appliance. It uses air (oxygen) from the room in which it is in-
stalled. Provisions for adequate combustion and ventilation air must be provided. Refer to
the National Fuel Gas Codes, ANSI Z233.1/NFPA 54, Section 5.3, Air for Combustion and Ven-
tilation.
This appliance may be installed in an aftermarket,* permanently located, manufactured (mo-
bile) home, where not prohibited by local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Brentwood
Models LCF18 and LCF24
For more information, visit www.desatech.com
Save this manual for future reference
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - Brentwood

WARNING: If the information in this manual is not fol-lowed exactly, a fi re or explosion may result causing property damage, personal injury, or loss

Page 2 - TABLE OF CONTENTS

115043-0110For more information, visit www.desatech.com6. With control knob pressed in, push down and release ignitor button. This will light pilot.

Page 3 - LOCAL CODES

115043-011111For more information, visit www.desatech.comTROUBLESHOOTING WARNING: Turn off log set and let cool before servicing. Only a qualifi ed se

Page 4 - INSTALLATION

115043-0112For more information, visit www.desatech.comOBSERVED PROBLEMWhen ignitor button is pressed, there is spark at pilot but no ignition (GA905

Page 5

115043-011313For more information, visit www.desatech.comTROUBLESHOOTINGContinued WARNING: If you smell gas• Shut off gas supply.• Do not try to l

Page 6

115043-0114For more information, visit www.desatech.comACCESSORIESACCESSORIESPurchase these log set accessories from your local dealer. If they can n

Page 7

115043-011515For more information, visit www.desatech.comPARTS LIST AND ILLUSTRATED PARTS BREAKDOWNThis list contains replaceable parts used in your

Page 8

115043-0116For more information, visit www.desatech.com1. Where will the product be used? m Living/Family Room ❍ Office/Warehouse ❍ Ut

Page 9 - OPERATING APPLIANCE

115043-011717For more information, visit www.desatech.com2701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004PostageRequiredTAPETAPE

Page 10 - PARTS NOT UNDER WARRANTY

115043-0118For more information, visit www.desatech.comNOTES_________________________________________________________________________________________

Page 11 - TROUBLESHOOTING

115043-011919For more information, visit www.desatech.comNOTES_______________________________________________________________________________________

Page 12

115043-012For more information, visit www.desatech.comSAFETY INFORMATIONCarbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble

Page 13

115043-0120For more information, visit www.desatech.comLIMITED WARRANTY - VENTED GAS LOGSDESA warrants this product to be free from defects on burner

Page 14 - ACCESSORIES

115043-0133For more information, visit www.desatech.comSAFETY INFORMATIONPRODUCT IDENTIFICATIONLOCAL CODESUNPACKINGOPTIONAL PRODUCT FEATURESPRODUCT I

Page 15 - PARTS AVAILABLE — NOT SHOWN

115043-014For more information, visit www.desatech.comINSTALLATION WARNING: Before installing in a solid fuel burning fi replace, the chimney fl ue

Page 16 - 115043-01

115043-0155For more information, visit www.desatech.comINSTALLATIONContinued CONNECTING TO GAS SUPPLY WARNING: A qualifi ed service person must con-ne

Page 17 - Required

115043-016For more information, visit www.desatech.comInstallation and Gas Connection1. Place the burner pan assembly in the center of the fi replace

Page 18

115043-0177For more information, visit www.desatech.comINSTALLATIONContinuedNatural Gas Installation1. Thread the gas control valve onto the burner

Page 19

115043-018For more information, visit www.desatech.comTESTING BURNER FOR LEAKS1. Generously apply noncorrosive leak detection fl uid to all connectio

Page 20 - WARRANTY INFORMATION

115043-0199For more information, visit www.desatech.comLIGHTING INSTRUCTIONSOPERATING APPLIANCEFOR YOUR SAFETYREAD BEFORE LIGHTING WARNING: If you do