UNVENTED (VENT-FREE) GAS COMPACT CLASSIC HEARTH
®
DUAL BURNER FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
Save this manual for future reference.
For more information, visit www.desatech.com
THERMOSTAT MODELS
CDCFTN, CDCFTP, VDCFTN, VDCFTP, FDCFTN, FDCFTP
REMOTE-READY MODELS
VDCFRN, VDCFRP, FDCFRN, FDCFRP
Shown with Optional Cabinet Mantel/Hearth Base Accessory
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a quali-
fied installer, service agency, or the gas supplier.
Vue de la page 0
1 2 3 4 5 6 ... 43 44

Résumé du contenu

Page 1 - DUAL BURNER FIREPLACE

UNVENTED (VENT-FREE) GAS COMPACT CLASSIC HEARTH®DUAL BURNER FIREPLACEOWNER’S OPERATION AND INSTALLATION MANUALSave this manual for future reference.Fo

Page 2 - TABLE OF CONTENTS

www.desatech.com 111244-01C10INSTALLATION ITEMSBefore installing fireplace, make sure you havethe items listed below.• external regulator (supplied by

Page 3 - SAFETY INFORMATION

www.desatech.com111244-01C11INSTALLATIONContinuedBUILT-IN FIREPLACEINSTALLATIONBuilt-in installation of this fireplace involves in-stalling fireplace

Page 4

www.desatech.com 111244-01C1210. If using optional brass trim kit, install the trimafter final finishing and/or painting of wall.See instructions incl

Page 5 - Fireplace

www.desatech.com111244-01C133. Place fireplace on wood base (see Figure 12).4. Place mantel around fireplace on base (seeFigure 12).5. Assemble perime

Page 6 - AND VENTILATION

www.desatech.com 111244-01C14INSTALLATIONContinued321OFFPILOTONHILOFigure 14 - Installing Blower BracketAssembly (Remote-Ready Unit Shown)WireHarnessB

Page 7

www.desatech.com111244-01C15For Built-In Installation WARNING: A licensed elec-trician must connect the wiringharness to electrical supply fol-lowing

Page 8

www.desatech.com 111244-01C16Installation must include an equipment shutoffvalve, union, and plugged 1/8" NPT tap. LocateNPT tap within reach for

Page 9

www.desatech.com111244-01C17INSTALLATIONContinuedWe recommend that you install a sediment trap insupply line as shown in Figure 20, page 16. Lo-cate s

Page 10 - INSTALLATION

www.desatech.com 111244-01C18INSTALLATIONContinued CAUTION: Make sure exter-nal regulator has been installedbetween propane/LP supply andfireplace. Se

Page 11

www.desatech.com111244-01C19OPTIONAL WIRELESS HAND-HELDREMOTE CONTROL ACCESSORIESRemote-Ready Models Only([C]GHRCB Series & [C]GHRCTBSeries)Instal

Page 12

www.desatech.com 111244-01C2WARNING: Improper installation, adjustment, altera-tion, service, or maintenance can cause injury or prop-erty damage. Ref

Page 13

www.desatech.com 111244-01C20INSTALLATIONContinued2. Connect one terminal of 25 ft. wire to the“TH” terminal on the control valve. Connectthe other te

Page 14

www.desatech.com111244-01C21IMPORTANT: The wire may be shortened butmust not be lengthened.4. Connect one bare wire end to each of the ter-minals of t

Page 15 - Continued

www.desatech.com 111244-01C22Note: You may be running this fireplacefor the first time after hooking up to gassupply. If so, the control knob may need

Page 16 - IMPORTANT:

www.desatech.com111244-01C23OPERATING FIREPLACEContinuedOPERATINGBLOWERThis blower has three settings: ON, OFF, andAUTO. In the ON position, the blowe

Page 17

www.desatech.com 111244-01C24OPERATING FIREPLACEContinued5. Press in and turn control knob counter-clockwise to the PILOT position.Press in control

Page 18

www.desatech.com111244-01C25OPERATING FIREPLACEContinuedOPTIONAL HAND-HELDREMOTE OPERATIONNote: All remote control accessories must bepurchased separa

Page 19

www.desatech.com 111244-01C26OPERATING FIREPLACEContinuedNote: Do not leave the hand-held remote in theAUTO mode close to the fireplace. The radianthe

Page 20

www.desatech.com111244-01C27INSPECTING BURNERSCheck pilot flame pattern and burner flame pat-terns often.PILOT FLAME PATTERNFigure 46 shows a correct

Page 21 - OPERATING FIREPLACE

www.desatech.com 111244-01C28create soot. We recommend that you clean the unitevery three months during operation and have fire-place inspected yearly

Page 22

www.desatech.com111244-01C29TROUBLESHOOTINGNote: All troubleshooting itemsare listed in order of operation. WARNING: Turn off and unplug fireplace and

Page 23

www.desatech.com111244-01C3SAFETY INFORMATION WARNING: This product con-tains and/or generates chemicalsknown to the State of Californiato cause cance

Page 24

www.desatech.com 111244-01C30POSSIBLE CAUSE1. Control knob not fullypressed in2. Control knob not pressed inlong enough3. Safety interlock system hasb

Page 25

www.desatech.com111244-01C31TROUBLESHOOTINGContinuedPOSSIBLE CAUSE1. Residues from manufacturingprocesses and log curing2. Not enough air3. Gas regula

Page 26

www.desatech.com 111244-01C32TROUBLESHOOTINGContinued WARNING: If you smell gas• Shut off gas supply.• Do not try to light any appliance.• Do not touc

Page 27 - MAINTENANCE

www.desatech.com111244-01C33SPECIFICATIONSThermostat Models:CDCFTP, VDCFTP CDCFTN, VDCFTN,FDCFTP FDCFTNBtu/Hr 17/26,000 17/26,000Type Gas Propane/LP G

Page 28 - WIRING DIAGRAM

www.desatech.com 111244-01C34ILLUSTRATED PARTS BREAKDOWNFIREBOX MODELSFDCF, VDC, AND CDCF8819191919191919199101010161710101463111213111516181616161616

Page 29 - TROUBLESHOOTING

www.desatech.com111244-01C35KEY PART NUMBERSNO. FDCF Models VDCF Models CDCF Models DESCRIPTION QTY.1 ** ** ** Outer Casing Top

Page 30

www.desatech.com 111244-01C36ILLUSTRATED PARTS BREAKDOWNTHERMOSTAT MODELSFDCFTP, FDCFTN, VDCFTP, VDCFTN, CDCFTP AND CDCFTN8756612241918151699171114313

Page 31

www.desatech.com111244-01C37PARTS LISTTHERMOSTAT MODELSThis list contains replaceable parts used in your fireplace. When ordering parts, follow the in

Page 32

www.desatech.com 111244-01C38ILLUSTRATED PARTS BREAKDOWNREMOTE-READY MODELSFDCFRN, FDCFRP, VDCFRN AND VDCFRPOFFPILOTONHILO1615151612121199910517181319

Page 33 - SPECIFICATIONS

www.desatech.com111244-01C39PARTS LISTREMOTE-READY MODELSThis list contains replaceable parts used in your fireplace. When ordering parts, follow the

Page 34 - ILLUSTRATED PARTS BREAKDOWN

www.desatech.com 111244-01C4SAFETY INFORMATIONContinued1. This appliance is only for use with the type ofgas indicated on the rating plate. This appli

Page 35 - PARTS LIST

www.desatech.com 111244-01C40ACCESSORIESNOTICE: All accessories maynot be available for all fireplacemodels.Purchase these fireplace accessories from

Page 36

www.desatech.com111244-01C41CABINET MANTEL AND FULLHEARTH BASEGMC80F Series - Oak FinishedCMA200F Series - Oak FinishedGMC81U Series - Unfinished Birc

Page 37

www.desatech.com 111244-01C42SERVICE HINTSWhen Gas Pressure Is Too Low• pilot will not stay lit• burners will have delayed ignition• fireplace will no

Page 38

www.desatech.com111244-01C43__________________________________________________________________________________________________________________________

Page 39

2701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004www.desatech.com111244-01Rev. C01/04NOT A UPC111244 01

Page 40 - ACCESSORIES

www.desatech.com111244-01C5PRODUCTIDENTIFICATIONIgnitor ButtonScreenFireplaceCabinetLogControl KnobFigure 1 - Vent-Free Compact Dual FlameFireplaceOFF

Page 41

www.desatech.com 111244-01C6HOOD ASSEMBLY WARNING: Always havescreen in place before operatingfireplace. This prevents exces-sive temperatures on fire

Page 42 - REPLACEMENT PARTS

www.desatech.com111244-01C7PROVIDING ADEQUATEVENTILATIONThe following are excerpts from National FuelGas Code, ANSI Z223.1/NFPA 54, Section 5.3, Airfo

Page 43 - 111244-01C

www.desatech.com 111244-01C8AIR FOR COMBUSTIONAND VENTILATIONContinuedExample:Gas water heater ______________ Btu/HrVent-free fireplace ______________

Page 44 - 111244 01

www.desatech.com111244-01C9INSTALLATIONNOTICE: This heater is intendedfor use as supplemental heat.Use this heater along with yourprimary heating syst