Save this manual for future reference.
DESA INTERNATIONAL
UNVENTED (VENT-FREE)
PROPANE/LP GAS LOG HEATER
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
If you cannot reach your gas sup-
plier, call the fire department.
Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage.
Refer to this manual for correct installa-
tion and operational procedures. For
assistance or additional information con-
sult a qualified installer, service agency,
or the gas supplier.
WARNING: This gas log set is for instal-
lation in a masonry solid fuel burning
fireplace, a U.L. listed manufactured
solid fuel burning fireplace or an AGA
design certified vent-free firebox listed
for use with these gas log models.
WARNING: This is an unvented gas-
fired heater. It uses air (oxygen) from
the room in which it is installed. Provi-
sions for adequate combustion and ven-
tilation air must be provided. Refer to
Air for Combustion and Ventilation
sec-
tion in this manual.
18" and 24" Variable
Manually-Controlled Models
FLAME-MAX
Standard Oak
Log Design
OWNERS OPERATION AND INSTALLATION MANUAL
Models Also Designed Certified as Vented Decorative Appliances
This appliance may be installed in an aftermarket* manufactured (mobile) home, where
not prohibited by state or local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
®
Patent Pending
FLAME-MAX
Premium Golden
Oak Log Design
24" Variable
Manually-Controlled Model
24" Variable
Manually-Controlled Model
FLAME-MAX
Premium Birch
Log Design
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - PROPANE/LP GAS LOG HEATER

Save this manual for future reference.DESA INTERNATIONALUNVENTED (VENT-FREE)PROPANE/LP GAS LOG HEATERWARNING: If the information in thismanual is not

Page 2 - INFORMATION

10103310INSTALLINGContinuedINSTALLATION AND CLEARANCES (Vent-Free Operation Only)Figure 4 - Minimum Clearance to Wall and CeilingWARNINGMaintain the m

Page 3

11103310INSTALLINGContinuedNOTICEManual control heaters may be used as a vented product. If so,you must always run heater with chimney flue damper ope

Page 4 - IDENTIFICATION

12103310INSTALLINGContinuedMinimum Non Combustible Material ClearancesIf Using MantelYou must have non combustible material(s) above the fireplace ope

Page 5 - WARNING

13103310INSTALLINGContinuedFloor ClearancesA. If installing appliance on the floor level, you must maintain the minimumdistance of 14" to combust

Page 6 - VENTILATION

14103310INSTALLINGContinuedINSTALLING DAMPER CLAMP ACCESSORY FORVENTED OPERATIONNote: When used as a vented heater, appliance must be installed only i

Page 7

15103310INSTALLINGContinuedINSTALLING HEATER BASE ASSEMBLYWARNING ICON G 001 WARNINGIf installing in a sunken fireplace, special care is needed. Youmu

Page 8

16103310INSTALLINGContinuedCONNECTING TO GAS SUPPLYNOTICEA qualified service person must connect heater to gas supply.Follow all local codes.WARNING I

Page 9

17103310INSTALLINGContinuedThe installer must supply an external regulator. The external regulator will reduceincoming gas pressure. You must reduce i

Page 10 - INSTALLING

18103310Tee JointPipeNippleCap3" MinimumSedimentTrapGasRegulatorFromExternal Regulator(11" W.C.** to14" W.C.Pressure)A.G.A. Design-Cert

Page 11

19103310ONPOSITIONOFFPOSITION3. Pressurize supply piping system by either using compressed air oropening propane supply tank valve.4. Check all joints

Page 12

2103310CONTENTSSECTION PAGESAFETYINFORMATIONWARNING ICON G 001 WARNINGSIMPORTANT: Read this owner’s manual carefully and completely beforetrying to as

Page 13

20103310INSTALLINGContinuedWARNING ICON G 001 WARNINGFailure to position the parts in accordance with these diagrams or failureto use only parts speci

Page 14

21103310INSTALLINGContinuedFor Premium ModelsIt is very important to install the logs exactly as instructed. Do not modify logs.Only use logs supplied

Page 15

22103310OPERATINGHEATERFOR YOUR SAFETY READ BEFORE LIGHTINGWARNING ICON G 001 WARNINGIf you do not follow these instructions exactly, a fire or explos

Page 16 - Follow all local codes

23103310WARNING ICON G 001 WARNINGDo not operate heater between PILOT and HIGH positions.WARNING ICON G 001 CAUTIONDo not try to adjust heating levels

Page 17 - WARNING ICON G001

24103310OPERATINGHEATERContinuedTO TURN OFF GAS TO APPLIANCEShutting Off Heater1. Press in and turn control knob clockwise Clockwise to the HIGH posit

Page 18

25103310CLEANINGANDMAINTENANCEWARNING ICON G001 WARNINGTurn off heater and let cool before cleaning.WARNING ICON G 001 CAUTIONYou must keep control ar

Page 19 - POSITION

26103310TROUBLE-SHOOTINGContinuedREMEDY1. Turn on gas supply oropen manual shutoffvalve2. Turn control knob toPILOT position3. Press in control knobwh

Page 20

27103310TROUBLE-SHOOTINGContinuedOBSERVEDPROBLEMBurner does not lightafter ODS/pilot is litDelayed ignitionburnerBurner backfiringduring combustionSli

Page 21

28103310TROUBLE-SHOOTINGContinuedWARNING ICON G 001 WARNINGIf you smell gas• Shut off gas supply.• Do not try to light any appliance.• Do not touch an

Page 22 - Continued

29103310TECHNICALSERVICEYou may have further questions about installation, operation, or troubleshooting.If so, contact DESA International’s Technical

Page 23 - Figure 23 - Pilot

3103310SAFETYINFORMATIONContinuedWARNING ICON G 001 WARNINGS ContinuedWARNING: Any change to this heater or its controls can be dangerous.1. This appl

Page 24 - INSPECTING

30103310ILLUSTRATEDPARTSBREAKDOWNFlame-MaxStandard Oak ModelsVYS18P and VYS24P41231221101121721568915141619221813191720-220-1201823

Page 25

31103310PARTS LISTThis list contains replaceable parts used in your heater. When ordering parts, followthe instructions listed under Replacement Parts

Page 26 - SHOOTING

32103310ILLUSTRATEDPARTSBREAKDOWNFlame-Max Premium Oakand Birch Log ModelsVYD24P and VYBD24P521111213 218212167109161517192181419320-220-1201841A1B

Page 27

33103310KEY PART NUMBER FORNO. VYD24P VYBD24P DESCRIPTION QTY.1A 103334-01 – Log, Premium Oak 11B – 103335-01 Log, Premium Birch 12 098276-01 098276-0

Page 28

34103310ACCESSORIESPurchase these heater accessories from your local dealer. If they can not supplythese accessories, call DESA International’s Parts

Page 29 - SPECIFICATIONS

35103310NOTES_________________________________________________________________________________________________________________________________________

Page 30 - BREAKDOWN

KEEP THIS WARRANTYWARRANTY INFORMATIONAlways specify model and serial numbers when communicating with the factory.We reserve the right to amend these

Page 31 - PARTS LIST

4103310PRODUCTIDENTIFICATIONFigure 1 - Product IdentificationControl KnobBack LogBase AssemblyPiezo IgnitorBurnerCrossover LogFront Log Flame-MaxSt

Page 32 - VYD24P and VYBD24P

5103310LOCAL CODESInstall and use heater with care. Follow all local codes. In the absence of localcodes, use the latest edition of The National Fuel

Page 33

6103310PROVIDING ADEQUATE VENTILATIONThe following is exerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1,Section 5.3, Air for Combustion and Ven

Page 34 - ACCESSORIES

7103310AIR FORCOMBUSTIONANDVENTILATIONContinuedDETERMINING AIR FLOW FOR HEATER LOCATIONDetermining if You Have a Confined or Unconfined SpaceUse this

Page 35

8103310AIR FORCOMBUSTIONANDVENTILATIONContinued WARNINGIf the area in which the heater may be operated is smaller thanthat defined as an unconfined sp

Page 36 - 103310-01

9103310INSTALLINGNOTICEA qualified service person must install heater. Follow all local codes.WARNING ICON G 001 WARNINGBefore installing in a solid f