Vue de la page 0
UNVENTED (VENT-FREE) GAS COMPACT CLASSIC HEARTH
®
DUAL BURNER FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
Save this manual for future reference.
For more information, visit www.desatech.com
THERMOSTAT MODELS
CDCFTNA, CDCFTPA, FDCFTN, FDCFTP, VDCFTN, VDCFTP
REMOTE-READY MODELS
CDCFNR, CDCFPR, FDCFRN, FDCFRP, VDCFRN, VDCFRP
Shown with Optional Cabinet Mantel/Hearth Base Accessory
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbors
phone. Follow the gas suppliers instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a quali-
fied installer, service agency, or the gas supplier.
Vue de la page 0
1 2 3 4 5 6 ... 47 48

Résumé du contenu

Page 1 - DUAL BURNER FIREPLACE

UNVENTED (VENT-FREE) GAS COMPACT CLASSIC HEARTH® DUAL BURNER FIREPLACEOWNER’S OPERATION AND INSTALLATION MANUALSave this manual for future reference.F

Page 2 - TABLE OF CONTENTS

www.desatech.com111244-01E10INSTALLATION ITEMSBefore installing fireplace, make sure you have the items listed below.• external regulator (supp

Page 3 - SAFETY INFORMATION

www.desatech.com111244-01E 11INSTALLATIONContinuedFigure 9 - Rough Opening for Installing in Corner Figure 8 - Rough Opening for Installing in Wall 43

Page 4 - IDENTIFICATION

www.desatech.com111244-01E1215"18"21"23"2 1/2"6"8"10"Note:All verticalmeasurementsare from top offireplaceopen

Page 5 - UNPACKING

www.desatech.com111244-01E 13INSTALLATIONContinued9. Use two 3" wood screws provided and attach base of fireplace to wooden mantel base (see Figu

Page 6 - AND VENTILATION

www.desatech.com111244-01E14INSTALLATIONContinuedInstalling Blower Accessory CAUTION: Label all wires prior to disconnection when servicing con

Page 7

www.desatech.com111244-01E 15INSTALLATIONContinuedFor Built-In Installation WARNING: A licensed elec-trician must connect the wiring harness to elec

Page 8

www.desatech.com111244-01E16Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap wit

Page 9

www.desatech.com111244-01E 17INSTALLATIONContinuedWe recommend that you install a sediment trap in supply line as shown in Figure 21, page 16. Locate

Page 10 - INSTALLATION

www.desatech.com111244-01E18INSTALLATIONContinued CAUTION: Make sure exter-nal regulator has been installed between propane/LP supply and fireplace. Se

Page 11

www.desatech.com111244-01E 19OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL ACCESSORIES Remote-Ready Models Only ([C]GHRCB Series & [C]GHRCTB Series)I

Page 12

www.desatech.com111244-01E2WARNING: Improper installation, adjustment, altera-tion, service, or maintenance can cause injury or prop-erty damage.

Page 13 - ACCESSORY GA3450TA

www.desatech.com111244-01E20INSTALLATIONContinued2. Connect one terminal of 25 ft. wire to the “TH” terminal on the control valve. Connect th

Page 14 - Continued

www.desatech.com111244-01E 21IMPORTANT: The wire may be shortened but must not be lengthened.4. Connect one bare wire end to each of th

Page 15

www.desatech.com111244-01E22LIGHTING INSTRUCTIONS WARNING: You must operate this fireplace with the screen in place. Make sure fireplace screen

Page 16

www.desatech.com111244-01E 23Figure 40 - Control Knob In The OFF PositionIgnitor ButtonControl Knob6. With control knob pressed in, press and r

Page 17

www.desatech.com111244-01E24OPERATING FIREPLACEContinuedNote: It is safe to operate fireplace with blower turned off. However, the blower helps distrib

Page 18

www.desatech.com111244-01E 25OPERATING FIREPLACEContinued6. With control knob pressed in, press and release ignitor button. This will light pil

Page 19

www.desatech.com111244-01E26REMOTEOFFONHILOINOUTOPERATING FIREPLACEContinuedNote: The burner may light if hand-held remote was on when selecto

Page 20

www.desatech.com111244-01E 27OPERATING FIREPLACEContinued2. The receiver continuously receives signals from the hand-held remote to control the room

Page 21

www.desatech.com111244-01E28BURNER FLAME PATTERNFigure 53 shows a correct burner flame pattern. Figure 54 shows an incorrect burner flame pattern. The i

Page 22 - OPERATING FIREPLACE

www.desatech.com111244-01E 29Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot as-sembly. There is a

Page 23

www.desatech.com111244-01E 3 WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling

Page 24

www.desatech.com111244-01E30TROUBLESHOOTING WARNING: Turn off and unplug fireplace and let cool before servicing. Only a qualified service person should

Page 25

www.desatech.com111244-01E 31POSSIBLE CAUSE1. Co nt ro l kn ob no t fu ll y pressed in2. Control knob not pressed in long enough3. Safety

Page 26

www.desatech.com111244-01E32TROUBLESHOOTINGContinuedPOSSIBLE CAUSE1. Residues from manufacturing processes and log curing2. Not enough air3. Gas re

Page 27 - INSPECTING BURNERS

www.desatech.com111244-01E 33TROUBLESHOOTINGContinued WARNING: If you smell gas• Shut off gas supply.• Do not try to light any appliance.• Do not to

Page 28 - CLEANING AND

www.desatech.com111244-01E34SPECIFICATIONSThermostat Models: CDCFTPA, VDCFTP, FDCFTP CDCFTNA, VDCFTN, FDCFTN Btu/Hr 17/26,000 17/26,000Type Gas Pr

Page 29 - WIRING DIAGRAM

www.desatech.com111244-01E 35SERVICE HINTSWhen Gas Pressure Is Too Low• pilot will not stay lit• burners will have delayed ignition• fireplace will

Page 30 - TROUBLESHOOTING

www.desatech.com111244-01E36881919191919191919910101016171010146311121311151618161616161616251616161674ILLUSTRATED PARTS BREAKDOWNFIREBOX MODELS CDCF

Page 31

www.desatech.com111244-01E 37KEY PART NUMBERSNO. FDCF Models VDCF Models CDCF Models DESCRIPTION QTY.1 ** ** ** Outer

Page 32

www.desatech.com111244-01E38ILLUSTRATED PARTS BREAKDOWNFIREBOX MODELS CDCFNR, CDCFPR81081414141414141419910102019221016171010631112132321241115161816

Page 33

www.desatech.com111244-01E 39KEYNO. PART NUMBER DESCRIPTION QTY.1 ** Outer Casing Top 12 ** Baffle 13 ** Outer Casin

Page 34 - SPECIFICATIONS

www.desatech.com111244-01E4PRODUCT IDENTIFICATIONIgnitor ButtonScreen FireplaceCabinetLogControl KnobFigure 1 - Vent-Free Compact Dual Flame Fireplace

Page 35 - REPLACEMENT PARTS

www.desatech.com111244-01E40ILLUSTRATED PARTS BREAKDOWNTHERMOSTAT MODELS FDCFTP, FDCFTN, VDCFTP, VDCFTN, CDCFTPA AND CDCFTNA87566122419181516991711143

Page 36 - ILLUSTRATED PARTS BREAKDOWN

www.desatech.com111244-01E 41PARTS LISTTHERMOSTAT MODELSThis list contains replaceable parts used in your fireplace. When ordering parts, follow the in

Page 37 - PARTS LIST

www.desatech.com111244-01E42ILLUSTRATED PARTS BREAKDOWNREMOTE-READY MODELS FDCFRN, FDCFRP, VDCFRN, VDCFRP, CDCFNR, CDCFPROFF PILOT ONHI

Page 38

www.desatech.com111244-01E 43 CDCFPR CDCFNRKEY FDCFRP FDCFRNNO. VDCFRP VDCFRN DESCRIPTION QTY.1 111069-01 111069-01 Dual Burner 12 099056

Page 39

www.desatech.com111244-01E44ACCESSORIESNOTICE: All accessories may not be available for all fireplace models.Purchase these fireplace accessories fro

Page 40

www.desatech.com111244-01E 45CORNER MANTEL WITH FULL HEARTH BASECMA208F Series - Dark OakCMA209U Series - Unfinished BirchFor all models. Space-saving

Page 41

www.desatech.com111244-01E46NOTES_____________________________________________________________________________________________________________________

Page 42

www.desatech.com111244-01E 47NOTES____________________________________________________________________________________________________________________

Page 43

2701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004www.desatech.com111244-01Rev. E08/04NOT A UPC111244 01

Page 44 - ACCESSORIES

www.desatech.com111244-01E 5OPTIONAL REMOTE CONTROL ACCESSORIES(For Remote-Ready Models Only)There are four optional remote controls that can b

Page 45

www.desatech.com111244-01E6HOOD ASSEMBLY WARNING: Always have screen in place before operating fireplace. This prevents exces-sive temperatures on fi

Page 46 - 111244-01E

www.desatech.com111244-01E 7PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Sect

Page 47 - 111244-01E 47

www.desatech.com111244-01E8AIR FOR COMBUSTION AND VENTILATIONContinued4. Compare the maximum Btu/Hr the space can support with the actual amoun

Page 48 - 111244 01

www.desatech.com111244-01E 9 CAUTION: This fireplace cre-ates warm air currents. These currents move heat to wall sur-faces next to fireplace. Insta