UNVENTED (VENT-FREE) GAS COMPACT CLASSIC HEARTH
®
DUAL BURNER FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
Save this manual for future reference.
For more information, visit www.desatech.com
THERMOSTAT MODELS
CDCFTNA, CDCFTPA, FDCFTN, FDCFTP, VDCFTN, VDCFTP
REMOTE-READY MODELS
CDCFNR, CDCFPR, FDCFRN, FDCFRP, VDCFRN, VDCFRP
Shown with Optional Cabinet Mantel/Hearth Base Accessory
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
•
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
—
Installation and service must be performed by a quali-
fied installer, service agency, or the gas supplier.
Vue de la page 0
1 2 3 4 5 6 ... 47 48

Résumé du contenu

Page 1 - DUAL BURNER FIREPLACE

UNVENTED (VENT-FREE) GAS COMPACT CLASSIC HEARTH® DUAL BURNER FIREPLACEOWNER’S OPERATION AND INSTALLATION MANUALSave this manual for future reference.F

Page 2 - TABLE OF CONTENTS

www.desatech.com111244-01F10INSTALLATION ITEMSBefore installing fireplace, make sure you have the items listed below.• external regulator (supp

Page 3 - SAFETY INFORMATION

www.desatech.com111244-01F 11INSTALLATIONContinuedFigure 9 - Rough Opening for Installing in Corner Figure 8 - Rough Opening for Installing in Wall 43

Page 4 - IDENTIFICATION

www.desatech.com111244-01F1215"18"21"23"2 1/2"6"8"10"Note:All verticalmeasurementsare from top offireplaceopen

Page 5 - UNPACKING

www.desatech.com111244-01F 13INSTALLATIONContinuedFigure 16 - Removing Top Louver and Opening Bottom LouverOFF PILOT ONHI LOT

Page 6 - AND VENTILATION

www.desatech.com111244-01F14INSTALLATIONContinuedInstalling Blower Accessory CAUTION: Label all wires prior to disconnection when servicing con

Page 7

www.desatech.com111244-01F 15INSTALLATIONContinuedFor Built-In Installation WARNING: A licensed elec-trician must connect the wiring harness to elec

Page 8

www.desatech.com111244-01F16Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap wit

Page 9

www.desatech.com111244-01F 17INSTALLATIONContinuedWe recommend that you install a sediment trap in supply line as shown in Figure 23, page 16. Locate

Page 10 - INSTALLATION

www.desatech.com111244-01F18INSTALLATIONContinued CAUTION: Make sure exter-nal regulator has been installed between propane/LP supply and fireplace. Se

Page 11

www.desatech.com111244-01F 19OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL ACCESSORIES Remote-Ready Models Only (HRC100 Series & HRC200 Series)Instal

Page 12 - OPTIONAL MANTEL INSTALLATION

www.desatech.com111244-01F2WARNING: Improper installation, adjustment, altera-tion, service, or maintenance can cause injury or prop-erty damage.

Page 13 - ACCESSORY GA3450TA

www.desatech.com111244-01F20INSTALLATIONContinued3. Route the 25 ft. wire to a convenient location to mount your thermostat (no outside wall). IMPORT

Page 14

www.desatech.com111244-01F 212. Reattach screen by placing the notches in the screen frame over the shoulder screws and pushing down.INSTALLATIO

Page 15

www.desatech.com111244-01F22LIGHTING INSTRUCTIONS WARNING: You must operate this fireplace with the screen in place. Make sure fireplace screen

Page 16

www.desatech.com111244-01F 236. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to

Page 17

www.desatech.com111244-01F24OPERATING FIREPLACEContinuedNote: It is safe to operate fireplace with blower turned off. However, the blower helps distrib

Page 18

www.desatech.com111244-01F 25OPERATING FIREPLACEContinued6. With control knob pressed in, press and release ignitor button. This will light pil

Page 19

www.desatech.com111244-01F26REMOTEOFFONHILOINOUTOPERATING FIREPLACEContinuedNote: The burner may light if hand-held remote was on when selecto

Page 20

www.desatech.com111244-01F 27OPERATING FIREPLACEContinuedNote: Do not hold the hand-held remote for a long time. Body temperature will affe

Page 21

www.desatech.com111244-01F28If pilot flame pattern is incorrect, as shown in Figure 53, page 27• turn fireplace off (see To Turn Off Gas to App

Page 22 - OPERATING FIREPLACE

www.desatech.com111244-01F 29Figure 56 - Injector Holder On Outlet Burner TubeBurner TubeInjector HolderPrimary Air Inlet Holes3. Blow air through th

Page 23

www.desatech.com111244-01F 3 WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling

Page 24

www.desatech.com111244-01F30TROUBLESHOOTING WARNING: Turn off and unplug fireplace and let cool before servicing. Only a qualified service person should

Page 25

www.desatech.com111244-01F 31POSSIBLE CAUSE1. Co nt ro l kn ob no t fu ll y pressed in2. Control knob not pressed in long enough3. Safety

Page 26

www.desatech.com111244-01F32TROUBLESHOOTINGContinuedPOSSIBLE CAUSE1. Residues from manufacturing processes and log curing2. Not enough air3. Gas re

Page 27 - INSPECTING BURNERS

www.desatech.com111244-01F 33TROUBLESHOOTINGContinued WARNING: If you smell gas• Shut off gas supply.• Do not try to light any appliance.• Do not to

Page 28 - CLEANING AND

www.desatech.com111244-01F34SPECIFICATIONSTHERMOSTAT MODELS:CDCFTPA, VDCFTP, FDCFTP• Rating: 17,000/26,000 Btu/Hr• Gas Type: Propane/LP Gas Only• I

Page 29 - WIRING DIAGRAM

www.desatech.com111244-01F 35SERVICE HINTSWhen Gas Pressure Is Too Low• pilot will not stay lit• burners will have delayed ignition• fireplace will

Page 30 - TROUBLESHOOTING

www.desatech.com111244-01F36881919191919191919910101016171010146311121311151618161616161616251616161674ILLUSTRATED PARTS BREAKDOWNFIREBOX MODELS CDCF

Page 31

www.desatech.com111244-01F 37PARTS LISTFIREBOX MODELS CDCFTNA, CDCFTPA, VDCFTN, VDCFTP, FDCFTN, FDCFTP VDCFRN, VDCFRP, FDCFRN AND FDCFRPThis list con

Page 32

www.desatech.com111244-01F38ILLUSTRATED PARTS BREAKDOWNFIREBOX MODELS CDCFNR AND CDCFPR81081414141414141419910101919201016171010631112132119221115161

Page 33

www.desatech.com111244-01F 39PARTS LISTFIREBOX MODELS CDCFNR AND CDCFPRThis list contains replaceable parts used in your fireplace. When ordering part

Page 34 - SPECIFICATIONS

www.desatech.com111244-01F4PRODUCT IDENTIFICATIONIgnitor ButtonScreenFireplace CabinetLogControl KnobFigure 1 - Vent-Free Compact Dual Flame Fireplace

Page 35 - REPLACEMENT PARTS

www.desatech.com111244-01F40ILLUSTRATED PARTS BREAKDOWNTHERMOSTAT MODELS FDCFTP, FDCFTN, VDCFTP, VDCFTN, CDCFTPA AND CDCFTNA87566122419181516991711143

Page 36 - ILLUSTRATED PARTS BREAKDOWN

www.desatech.com111244-01F 41KEY NO. PART NO. DESCRIPTION QTY.1 111069-01 Dual Burner • • • • 12 099056-29 Injector, LP • • 1099056-34 Injector, NG •

Page 37 - PARTS LIST

www.desatech.com111244-01F42ILLUSTRATED PARTS BREAKDOWNREMOTE-READY MODELS FDCFRN, FDCFRP, VDCFRN, VDCFRP, CDCFNR AND CDCFPROFF PILOT ONHI

Page 38

www.desatech.com111244-01F 43PARTS LISTREMOTE-READY MODELSThis list contains replaceable parts used in your fireplace. When ordering parts, follow the

Page 39

www.desatech.com111244-01F44ACCESSORIESNOTICE: All accessories may not be available for all fireplace models.Purchase these fireplace accessories fro

Page 40

www.desatech.com111244-01F 45WALL-MOUNT THERMOSTAT SWITCH - GWMT1(Not Shown)For all remote-ready models. The desired com-fort setting can be selected

Page 41

www.desatech.com111244-01F46NOTES_____________________________________________________________________________________________________________________

Page 42

www.desatech.com111244-01F 47NOTES____________________________________________________________________________________________________________________

Page 43

2701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004www.desatech.com111244-01Rev. F09/05NOT A UPC111244 01

Page 44 - ACCESSORIES

www.desatech.com111244-01F 5OPTIONAL REMOTE CONTROL ACCESSORIES(For Remote-Ready Models Only)There are four optional remote controls that can b

Page 45

www.desatech.com111244-01F6HOOD ASSEMBLY WARNING: Always have screen in place before operating fireplace. This prevents exces-sive temperatures on fi

Page 46 - 111244-01F

www.desatech.com111244-01F 7PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Sect

Page 47 - 111244-01F 47

www.desatech.com111244-01F8AIR FOR COMBUSTION AND VENTILATIONContinued4. Compare the maximum Btu/Hr the space can support with the actual amoun

Page 48 - 111244 01

www.desatech.com111244-01F 9 CAUTION: This fireplace cre-ates warm air currents. These currents move heat to wall sur-faces next to fireplace. Insta