WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbors
phone. Follow the gas suppliers instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
UNVENTED (VENT-FREE) GAS LOG HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
24" AND 30" REMOTE-READY MODELS:
VRL24NR, VRL24PR, VRL30NR, VRL30PR, CSG3924NR,
CSG3924PR, CTB3924NR, CTB3924PR, CSG3930NR, CSG3930PR
24" AND 30" THERMOSTAT MODELS:
VRL24NT, VRL24PT, VRL30NT, VRL30PT, CSG3924NT, CSG3924PT,
CTB3924NT, CTB3924PT
Remote-Ready Models Also Design-Certified As Vented Decorative Appliances
Vue de la page 0
1 2 3 4 5 6 ... 43 44

Résumé du contenu

Page 1

Save this manual for future reference.For more information, visit www.desatech.comWARNING: If the information in this manual is not fol-lowed exactly,

Page 2 - TABLE OF CONTENTS

www.desatech.com110021-01M10LOG SIZING REQUIREMENTS Minimum Firebox Size Log Front Rear Size Height Depth Width Width* 24" 17&quo

Page 3 - SAFETY INFORMATION

www.desatech.com110021-01M 11Noncombustible Requirements for Material Distance (A) Safe Installation12" or more Noncombustible material okay.B

Page 4

www.desatech.com110021-01M12MinimumNoncombustible Material 8"Min.12"15"18"All minimum distances arein inches20"2 1/2"6&q

Page 5 - IDENTIFICATION

www.desatech.com110021-01M 13Area of Various Standard Round Flues Diameter (ins.) Area (sq. ins.) 5" 20 sq. inches 6" 29 sq. inches 7

Page 6 - AND VENTILATION

www.desatech.com110021-01M14INSTALLATIONContinuedIMPORTANT: Make sure the heater burners are level. If heater is not level, heater will not work prope

Page 7

www.desatech.com110021-01M 15Installation Items NeededBefore installing heater, make sure you have the items listed below.• external regulator (suppl

Page 8

www.desatech.com110021-01M16INSTALLATIONContinuedCHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections, internal and external to un

Page 9

www.desatech.com110021-01M 17Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)1. Close equipment shutoff valve (see Figure 16).2. Pressurize

Page 10 - INSTALLATION

www.desatech.com110021-01M18INSTALLATIONContinuedINSTALLING LOGS WARNING: Failure to posi-tion the parts in accordance with these diagrams or

Page 11

www.desatech.com110021-01M 19INSTALLATIONContinuedFigure 22 - Installing Log #5 (Right) and Log #6 (Left) (Model CSG3924NR Shown)Log #5Log #6Log #4Log

Page 12

www.desatech.com110021-01M2WARNING: Improper installation, adjustment, altera-tion, service or maintenance can cause injury or prop-erty damage. R

Page 13

www.desatech.com110021-01M20 WHAT TO DO IF YOU SMELL GAS• Do not try to light any appliance.• Do not touch any electric switch; do not use any phon

Page 14

www.desatech.com110021-01M 21OPERATING HEATERContinuedNote: Home owners generally prefer to op-erate their heater with the chimney damper

Page 15

www.desatech.com110021-01M22OPERATING HEATERContinuedFOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol-low these instructions exactly

Page 16

www.desatech.com110021-01M 23OPERATING HEATERContinuedNote: AUTO is only functional when using GWMT1 or GWMS2 optional accessories.11. To light the

Page 17

www.desatech.com110021-01M24OPERATING HEATERContinuedTO TURN OFF GAS TO APPLIANCEShutting Off Heater1. Turn control knob clockwise to the OFF positi

Page 18

www.desatech.com110021-01M 25Locks System to Prevent Accidental IgnitionManual Mode1. Press the POWER and LOCK buttons together to turn on the h

Page 19

www.desatech.com110021-01M26CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control are

Page 20 - OPERATING HEATER

www.desatech.com110021-01M 271. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.2. Inspect burners, pi

Page 21 - TO APPLIANCE

www.desatech.com110021-01M28TROUBLESHOOTING WARNING: Turn off and unplug heater and let cool before servicing. Only a qualified service person should s

Page 22

www.desatech.com110021-01M 29TROUBLESHOOTINGContinued OBSERVED PROBLEMODS/pilot lights but flame goes out when control knob is re-leasedOne or mor

Page 23 - Continued

www.desatech.com110021-01M 3SAFETY INFORMATION WARNING: This product con-tains and/or generates chemicals known to the State of California to cause ca

Page 24 - (MODEL HRC200)

www.desatech.com110021-01M30TROUBLESHOOTINGContinued OBSERVED PROBLEMYellow flame in front/middle burner during burner combustion (VRL and CSG mode

Page 25 - INSPECTING BURNERS

www.desatech.com110021-01M 31OBSERVED PROBLEMHeater produces unwanted odorsHeater shuts off in use (ODS operates)Gas odor even when control kno

Page 26 - MAINTENANCE

www.desatech.com110021-01M32OPTIONAL POSITIONING OF THERMOSTAT SENSING BULBFOR MASONRY AND FACTORY-BUILT METAL FIREPLACEIf your log set cycles to pilo

Page 27

www.desatech.com110021-01M 33Capillary Thermostat Sensing Bulb Do Not Crimp Capillary Adhesive-backed Mounting Clip Figure 48 - Positioning the Thermo

Page 28 - TROUBLESHOOTING

www.desatech.com110021-01M34SPECIFICATIONS 24" Thermostat-Controlled 30" Thermostat-ControlledBtu (Variable) 10,000/40,000 10,000/40,0

Page 29

www.desatech.com110021-01M 35ILLUSTRATED PARTS BREAKDOWNLOGS PART NUMBER CSG3924NT CSG3924PT CSG3924NR CSG3924PR VRL24NT VRL30N

Page 30

www.desatech.com110021-01M36ILLUSTRATED PARTS BREAKDOWNTHERMOSTAT-CONTROLLED MODELSVRL24NT, VRL24PT, VRL30NT, VRL30PTCSG3924NT, CSG3924PT, CTB3924NT,

Page 31

www.desatech.com110021-01M 37PARTS LISTTHERMOSTAT-CONTROLLED MODELSThis list contains replaceable parts used in your heater. When ordering parts, foll

Page 32 - SENSING BULB

www.desatech.com110021-01M38ILLUSTRATED PARTS BREAKDOWNREMOTE-READY MODELSVRL24NR, VRL24PR, VRL30NR, VRL30PRCSG3924NR, CSG3924PR, CTB3924NR, CTB3924PR

Page 33 - WIRING DIAGRAM

www.desatech.com110021-01M 39PARTS LISTREMOTE-READY MODELSThis list contains replaceable parts used in your heater. When ordering parts, follow the in

Page 34 - SPECIFICATIONS

www.desatech.com110021-01M4SAFETY INFORMATIONContinued9. Before using furniture polish, wax, carpet cleaner or similar products, turn heater off

Page 35 - ILLUSTRATED PARTS BREAKDOWN

www.desatech.com110021-01M40REPLACEMENT PARTSNote: Use only original replacement parts. This will protect your warranty coverage for parts repla

Page 36

www.desatech.com110021-01M 41ACCESSORIESNOTICE: All accessories may not be available for all fireplace models.Purchase these heater accessories from

Page 37 - PARTS LIST

www.desatech.com110021-01M42__________________________________________________________________________________________________________________________

Page 38

www.desatech.com110021-01M 43_________________________________________________________________________________________________________________________

Page 39

2701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004www.desatech.com110021-01Rev. M07/05NOT A UPC110021 01

Page 40 - SERVICE HINTS

www.desatech.com110021-01M 5OPTIONAL REMOTE CONTROL ACCESSORIESThere are four optional remote controls that can be purchased separately for

Page 41 - ACCESSORIES

www.desatech.com110021-01M6UNPACKING CAUTION: Do not remove the data plates from the grate as-sembly. The data plates contain important warranty

Page 42 - 110021-01M

www.desatech.com110021-01M 7AIR FOR COMBUSTION AND VENTILATIONContinued40,00031,50071,500Unusually tight construction is defined as construction where:

Page 43 - 110021-01M 43

www.desatech.com110021-01M8INSTALLATIONNOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heati

Page 44 - 110021 01

www.desatech.com110021-01M 9 WARNING: Installation and repair should be done by a quali-fied service person. The appliance should be inspected befor

Commentaires sur ces manuels