Vue de la page 0
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch
Do not use any phone in your building.
Immediately call your gas supplier from a neighbors
phone. Follow the gas suppliers instructions.
If you cannot reach your gas supplier, call the fire de
-
partment.
WARNING: Improper instal-
lation, adjustment, altera
-
tion, service or maintenance
can cause injury or property
damage. Refer to this manual
for correct installation and
operational procedures.
For assistance or additional
information consult a quali
-
fied installer, service agency
or the gas supplier.
This appliance may be installed in an aftermarket*, permanently located, manufactured (mo-
bile) home, where not prohibited by state or local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance
is not convertible for use with other gases, unless a certified kit is used.
WARNING: If the information in this manual is not followed
exactly, a fire or explosion may result causing property dam-
age, personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service
must be performed by a
qualified installer, service
agency or the gas supplier.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
DIRECT-VENT FIREPLACE
OWNER’S OPERATION AND
INSTALLATION MANUAL
Save this manual for future reference.
For more information, visit www.desatech.com
NATURAL GAS MODELS (V)VC42N SERIES
PROPANE/LP GAS MODEL (V)VC42P SERIES
Vue de la page 0
1 2 3 4 5 6 ... 39 40

Résumé du contenu

Page 1 - DIRECT-VENT FIREPLACE

FOR YOUR SAFETYWHAT TO DO IF YOU SMELL GAS• Do not try to light any appliance.• Do not touch any electrical switch• Do not use any phone in your bu

Page 2 - TABLE OF CONTENTS

www.desatech.com116236-01A10Horizontal High Wind Square TerminationWall Firestop45° ElbowFigure 14 - Horizontal Termination Configuration for Square or

Page 3 - LOCAL CODES

1111www.desatech.com116236-01AFigure 15 - Horizontal Termination Configuration for Corner Installation Using One 90° ElbowSquare Termination Wall Fires

Page 4 - PREPARATION

www.desatech.com116236-01A12Venting with Two 90° Elbows Vertical (V) Horizontal (H1) + Horizontal (H2) 5' min. 6' max. 6' min.

Page 5

1313www.desatech.com116236-01AINSTALLATION FOR VERTICAL TERMINATIONNote: Vertical restrictor must be installed in all vertical installa-tions.1. Dete

Page 6 - LOCATION OF TERMINATION CAP

www.desatech.com116236-01A14VENTING INSTALLATION INSTRUCTIONSContinuedVertical Termination ConfigurationsFigures 21 through 24 show four different confi

Page 7

1515www.desatech.com116236-01AVENTING INSTALLATION INSTRUCTIONSContinuedVertical VentingV = 40' max.Figure 24 - Vertical Venting Configuration Wit

Page 8

www.desatech.com116236-01A16CHECK GAS TYPEUse proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not insta

Page 9

1717www.desatech.com116236-01AFigure 26 - Attaching Speed Control to Firebox Speed Control Control Shaft Locknut Control Knob Switch BracketBlower Plu

Page 10 - INSTRUCTIONS

www.desatech.com116236-01A18Figure 29 - Blower Wiring Diagram for Thermostat-Controlled Models Blower Wiring Diagram CAUTION: Label all wires prior to

Page 11

1919www.desatech.com116236-01AFIREPLACE INSTALLATIONContinuedFIREPLACE INSTALLATIONInstalling Gas Piping to Fireplace Location (Cont.)Connecting Firep

Page 12

www.desatech.com116236-01A2SAFETY INFORMATION WARNING: This product contains and/or generates chemicals known to the State of California to cause

Page 13

www.desatech.com116236-01A20Figure 33 - Equipment Shutoff ValveOpenClosedEquipment Shutoff ValveFigure 35 - Checking Gas Joints for Natural Gas Firepl

Page 14

2121www.desatech.com116236-01AFIREPLACE INSTALLATIONContinuedFIREPLACE INSTALLATIONInstalling Optional Wireless Hand-Held Remote Control - GHRCB and G

Page 15

www.desatech.com116236-01A22LockUnlockGlass FrameAssemblyScrewFigure 42 - Removing/Replacing Glass DoorHingeRemoving Glass DoorsIf replacement of glas

Page 16 - Model BK Installation

2323www.desatech.com116236-01AFIREPLACE INSTALLATIONContinuedFIREPLACE INSTALLATIONInstalling Optional Brick Liner Models BL42DA(SA) and BL42DHA(SA)OP

Page 17 - FIREPLACE INSTALLATION

www.desatech.com116236-01A24OFF PILOT LO IH ON Figure 45 - Control ValvePiezo IgnitorGas Control KnobVariable Control KnobOPERATING

Page 18 - Installation Items Needed

2525www.desatech.com116236-01AOPERATING FIREPLACEOptional Hand-Held Remote Operation (Cont.)OPERATING FIREPLACEContinuedON/OFF SERIES MODEL GHRCB Hold

Page 19

www.desatech.com116236-01A26OPERATING OPTIONAL BLOWER ACCESSORYLocate the blower controls by opening the lower louver panel on the fireplace. Blower co

Page 20

2727www.desatech.com116236-01ACLEANING AND MAINTENANCEGlass DoorPilot and BurnersLogsVenting SystemCLEANING AND MAINTENANCE WARNING: Turn off fireplace

Page 21 - Installing Remote Receiver

www.desatech.com116236-01A28TROUBLESHOOTINGNote: All troubleshooting items are listed in order of operation. WARNING: Turn off heater and let c

Page 22

2929www.desatech.com116236-01ATROUBLESHOOTINGOBSERVED PROBLEMBurner does not light after pilot is litDelayed ignition burnerBurner backfiring during co

Page 23

33www.desatech.com116236-01ASAFETY INFORMATIONContinuedPRODUCT IDENTIFICATIONFigure 1 - Direct-Vent Fireplace with Millivolt IgnitionLOCAL CODESInstal

Page 24 - OPERATING FIREPLACE

www.desatech.com116236-01A30TROUBLESHOOTINGContinued WARNING: If you smell gas• Shut off gas supply.• Do not try to light any appliance.• Do not t

Page 25

3131www.desatech.com116236-01A Btu 25,000/36,000 Btu/hr 23,000/33,000 Btu/hrGas Type Natural Propane/LPIgnition Piezo PiezoManifold Pressure 3.

Page 26

www.desatech.com116236-01A32ILLUSTRATED PARTS BREAKDOWNModels VC42N, VC42P, VVC42N and VVC42P SeriesILLUSTRATED PARTS BREAKDOWNMODELSVC42N, VC42P, VVC

Page 27 - CLEANING AND MAINTENANCE

3333www.desatech.com116236-01APARTS LISTModels VC42N, VC42P, VVC42N and VVC42P SeriesPARTS LISTMODELSVC42N, VC42P, VVC42N AND VVC42P SERIESThis list c

Page 28 - OBSERVED PROBLEM

www.desatech.com116236-01A34715101211223139112122TPTH TP TH612141817171819201614845ILLUSTRATED PARTS BREAKDOWNBURNER ASSEMBLY FOR MODELSVC42N, VC42P,

Page 29

3535www.desatech.com116236-01APARTS LISTBURNER ASSEMBLY FOR MODELSVC42N, VC42P, VVC42N AND VVC42P SERIESThis list contains replaceable parts used in y

Page 30

www.desatech.com116236-01A36ACCESSORIESPurchase these fireplace accessories from your local retailer. If they can not supply these accessories, call DE

Page 31 - When Gas Pressure Is Too Low

3737www.desatech.com116236-01A1. Where will the product be used? � Living/Family Room � Office/Warehouse � Utility Shed/Outbuilding

Page 32 - ILLUSTRATED PARTS BREAKDOWN

www.desatech.com116236-01A382701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004PostageRequiredTAPETAPE

Page 33 - PARTS LIST

3939www.desatech.com116236-01ATAPENOTES_______________________________________________________________________________________________________________

Page 34

www.desatech.com116236-01A4PRODUCT FEATURESThese are a few facts that can help you understand and enjoy your direct-vent fireplace:• The venting syste

Page 35

LIMITED WARRANTYDIRECT-VENT FIREPLACEDESA warrants this product to be free from defects in materials and components for two (2) years from the date of

Page 36 - (Not Shown)

55www.desatech.com116236-01AABEFGHDCNailing Tabs8CLEARANCESMinimum clearances to combustibles for the fireplace are as follows:*Back and sides 0"

Page 37 - 116236-01A

www.desatech.com116236-01A6FixedClosedOpenableFixedClosedOpenableVVVVVVVVXXVXGGJFBBKNHIANELDBMACBVVAGGBTERMINATION CAPAIR SUPPLY INLETGAS METER RESTRI

Page 38 - Required

77www.desatech.com116236-01AThese models are tested and approved for use with DESA (direct-vent) pipe components and terminations.The venting system m

Page 39

www.desatech.com116236-01A8INSTALLATION PLANNINGThere are two basic types of direct-vent installation:• Horizontal Termination• Vertical Termination

Page 40 - 116236 01

99www.desatech.com116236-01A WARNING: Do not recess vent termination into any wall. This will cause a fire hazard.6. Noncombustible Exterior Wall: Pos