Desa L32 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Foyers Desa L32. Desa L32 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 44
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Save this manual for future reference.
For more information, visit www.desatech.com
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
UNVENTED (VENT-FREE) FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
MANUALLY CONTROLLED
MODELS
NATURAL GAS
(V)L32(HN, LHN)
(V)L36(EN, LEN)
PROPANE/LP GAS
(V)L32(HP, LHP)
(V)L36(EP, LEP)
REMOTE CONTROL READY
MODELS
NATURAL GAS
(V)L36(ZNR, LZNR)
(V)L42(ZNR, LZNR)
PROPANE/LP GAS
(V)L36(ZPR, LZPR)
(V)L42(ZPR, LZPR)
Vue de la page 0
1 2 3 4 5 6 ... 43 44

Résumé du contenu

Page 1

Save this manual for future reference.For more information, visit www.desatech.comWARNING: If the information in this manual is not fol-lowed exactly,

Page 2 - TABLE OF CONTENTS

www.desatech.com115254-01A10B. Clearances from the top of the firebox opening to the ceiling should not be less than 42 inches. C. When the firebox is

Page 3 - SAFETY INFORMATION

www.desatech.com115254-01A 11INSTALLATIONContinued1. Frame in rough opening. The firebox fram-ing should be constructed of 2 x 4 lumber or heavier.

Page 4 - LOCAL CODES

www.desatech.com115254-01A12INSTALLING FIREBOX USING OPTIONAL ACCESSORY MANTELS WARNING: A qualified ser-vice person must install firebox. Follow all lo

Page 5 - LOCATING FIREBOX

www.desatech.com115254-01A 13INSTALLATIONContinued INSTALLING OPTIONAL BLOWER ACCESSORIESNOTICE: The firebox identifica-tion label (including model num-

Page 6

www.desatech.com115254-01A142. Attach green ground wire from power cord to blower housing using screw provided (see Figure 14, page 13). Tighten s

Page 7 - AND VENTILATION

www.desatech.com115254-01A 15INSTALLATIONContinued HARD-WIRING FIREBOXNOTICE: A qualified electrician must connect electrical wiring to duplex outlet f

Page 8

www.desatech.com115254-01A16INSTALLATIONContinued CONNECTING TO GAS SUPPLY WARNING: This appliance requires a 1/2" NPT (National Pipe Thre

Page 9

www.desatech.com115254-01A 17Tee Cap PipeJoint NippleWe recommend that you install a sediment trap in supply line as shown in Figures 21 and 22,

Page 10 - INSTALLATION

www.desatech.com115254-01A18Propane/LP Supply TankPRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)1. Disconne

Page 11 - Continued

www.desatech.com115254-01A 19INSTALLING LOGS (Models (V)L32HN, (V)L32LHN. (V)L32HP and (V)L32LHP WARNING: Failure to posi-tion the parts in accord

Page 12 - Follow all local codes

www.desatech.com115254-01A2WARNING: Improper installation, adjustment, altera-tion, service or maintenance can cause injury or prop-erty damage. R

Page 13 - ACCESSORIES

www.desatech.com115254-01A20Figure 30 - Installing Rear Log (#3)Figure 31 - Installing Crossover Log (#4)INSTALLING LOGS Models (V)L36(ZNR, LZNR, ZPR,

Page 14

www.desatech.com115254-01A 21Figure 33 - Installing Top LogsFigure 34 - Installing Front LogsMiddle Log Top Left Log Top Right Log Left Front Log Righ

Page 15

www.desatech.com115254-01A22LIGHTING INSTRUCTIONS WARNING:• If fireplace has glass doors, never operate this heater with glass doors closed. If yo

Page 16

www.desatech.com115254-01A 23OPERATING FIREPLACEContinued VARIABLE CONTROL OPERATIONThe variable control valve can be set to any heat setting an

Page 17

www.desatech.com115254-01A24LIGHTING INSTRUCTIONS WARNING• If fireplace has glass doors, never operate this heater with glass doors closed. If you

Page 18

www.desatech.com115254-01A 25OPERATING FIREPLACEContinued 9. Slightly push in and turn control knob coun-terclockwise to the ON position.10. Wait o

Page 19

www.desatech.com115254-01A26OPERATING FIREPLACEContinued Figure 41 - On/Off Hand-Held Remote Control Unit (GHRCB)Control Button Turns Burners On and O

Page 20

www.desatech.com115254-01A 27INSPECTING BURNERSCheck pilot flame pattern and burner flame pat-terns often.PILOT FLAME PATTERNFigure 43 shows a corre

Page 21 - OPERATING FIREPLACE

www.desatech.com115254-01A28CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control ar

Page 22

www.desatech.com115254-01A 29TROUBLESHOOTING WARNING: Turn off and unplug heater and let cool before servicing. Only a qualified service person should

Page 23

www.desatech.com115254-01A 3SAFETY INFORMATION WARNING: This product con-tains and/or generates chemicals known to the state of California to cause ca

Page 24

www.desatech.com115254-01A30TROUBLESHOOTINGContinued POSSIBLE CAUSE1. Cont r ol k nob not full y pressed in2. Control knob not pressed in long e

Page 25

www.desatech.com115254-01A 31TROUBLESHOOTINGContinued POSSIBLE CAUSE1. Burner orifice is clogged or damaged2. Damaged burner3. Gas regulator def

Page 26

www.desatech.com115254-01A32 WARNING: If you smell gas• Shut off gas supply.• Do not try to light any appliance.• Do not touch any electrical switc

Page 27 - INSPECTING BURNERS

www.desatech.com115254-01A 33Manually-Controlled Models (V)L32(HN, LHN, HP, LHP) (V)L36(EN, LEN, EP, LEP)Btu (Variable) 16,000/27,000 20,000/33,0

Page 28 - MAINTENANCE

www.desatech.com115254-01A34SERVICE HINTSWhen Gas Pressure Is Too Low• pilot will not stay lit• burners will have delayed ignition• heater will not

Page 29 - TROUBLESHOOTING

www.desatech.com115254-01A 35ACCESSORIESNOTICE: All accessories may not be available for all fireplace models.Purchase these firebox accessories from yo

Page 30

www.desatech.com115254-01A363235333637344828404041393833302946 47 1236794816151127241344434238451412104918192526232221203131517ILLUST

Page 31

www.desatech.com115254-01A 37PARTS LISTThis list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed u

Page 32

www.desatech.com115254-01A38ILLUSTRATED PARTS BREAKDOWNMANUAL MODELS L36EN, L36LEN, L36EP, L36LEP, VL36EN, VL36LEN, VL36EP AND VL36LEP2745473735323641

Page 33 - WIRING DIAGRAM

www.desatech.com115254-01A 39PARTS LISTThis list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed u

Page 34 - REPLACEMENT PARTS

www.desatech.com115254-01A4PRODUCT FEATURESOPERATIONThis firebox is designed for use with approved ANSI Z21.11.2 decorative type unvented room heaters.

Page 35

www.desatech.com115254-01A40273540 3234345142344150314338393733412512348111213142023/2422192118171548471049546934293628304544761626ILLUSTRATED

Page 36 - ILLUSTRATED PARTS BREAKDOWN

www.desatech.com115254-01A 41PARTS LISTThis list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed u

Page 37 - PARTS LIST

www.desatech.com115254-01A42ILLUSTRATED PARTS BREAKDOWN AND PARTS LISTLOG SETS FOR MODELS L36EN, L36LEN, L36EP, L36LEP, VL36EN, VL36LEN, VL36EP AND VL

Page 38

www.desatech.com115254-01A 43ILLUSTRATED PARTS BREAKDOWN AND PARTS LISTLOG SETS FOR MODELS L36ZNR, L36LZNR, L36ZPR, L36LZPR, VL36ZNR, VL36LZNR, VL36ZP

Page 39

LIMITED WARRANTY VENT-FREE FIREPLACEDESA warrants this product to be free from defects in materials and components for four (4) years from the date of

Page 40

www.desatech.com115254-01A 5PRODUCT SPECIFICATIONS32" MODELS251/8"291/2"347/16"363/8"Standoffs221/2"4"291/2"16

Page 41 - PARTS AVAILABLE NOT SHOWN

www.desatech.com115254-01A6PRODUCT SPECIFICATIONSContinuedFigure 2 - Firebox Dimensions (36" and 42" Models)36" AND 42" MODELSNote

Page 42 - VL36LEN, VL36EP AND VL36LEP

www.desatech.com115254-01A 7AIR FOR COMBUSTION AND VENTILATION WARNING: This firebox shall not be installed in a confined space or unusually tig

Page 43

www.desatech.com115254-01A8AIR FOR COMBUSTION AND VENTILATIONContinued1. Determine the volume of the space (length x width x height). Length x Width

Page 44 - WARRANTY INFORMATION

www.desatech.com115254-01A 9AIR FOR COMBUSTION AND VENTILATIONContinuedFigure 4 - Ventilation Air from OutdoorsVentilation Air From OutdoorsProvide ex