Desa H Manuel d'utilisateur Page 7

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 6
108795-01F
7
7
For more information, visit www.desatech.com
For more information, visit www.desatech.com
MANTEL CLEARANCES AND WALL DETAILS
A combustible mantle shelf maybe installed a maximum 12" (229mm)
from the wall. Figures 5 and 6 show the minimum allowable distances
from various combustible mantle components in relation to the fire-
place opening.
Spacer
3" (76mm)
1
1
/
2
"
(38mm) Max.
B
6" (152mm)
A
12"
(229mm)
Combustible
Materials
Header
Figure 5 - Mantel Clearances - Side View (Cross Section)
1
1
/
2
" (38mm)
Max.
3" (76mm)
Max.
6" (152mm)
Max.
A
B
Outer Surround
Combustible
Material May
Be Used
TOP VIEW
SAFE
ZONE
Perpendicular
Wall
Figure 6 - Side Clearances - Top View (Cross Section)
M36(B,H) M42(B,H)
VM36(B,H) VM42(B,H)
A 9" (229mm) 6" (152mm)
B 12" (305mm) 9" (229mm)
PRE-INSTALLATION PREPARATION
Mantel Clearances and Wall Details
PRE-INSTALLATION
PREPARATION
Continued
M36(B,H) M42(B,H)
VM36(B,H) VM42(B,H)
A 14" (356mm) 15" (381mm)
B 8" (203mm) 9" (229mm)
Vue de la page 6